  • OMA-406-O2 Analyzer
OMA-406-O2 Oxygen Analyzer main view

OMA-406-O2 Analyzer

Developed from decades of industry-leading experience, the OMA-406-O2 analyzer is designed from the ground up to provide dependable sulfur dioxide and oxygen analysis. By incorporating a field-proven dispersive spectrometer and an advanced paramagnetic oxygen detector with a user-friendly display, on-line analysis has never been easier.

Request a Quote

Features

  • Convient 19” form factor that fits a standard size rack.
  • Easy to use touchscreen HMI.
  • Application oriented design that incorporates a dispersive spectrometer and paramagnetic oxygen detector.
  • Flexible signal output options that include 4-20mA, RS-232, RS-485, and MODBUS TCP/IP.

Applications

The OMA-406-O2 can be used to monitor sulfur dioxide and oxygen in the following processes:

  • Continuous emissions monitoring.

Technology

Paramagnetic Oxygen Detection

  • Unlike most gases oxygen is paramagnetic. This means that it is weakly attracted to a magnetic field when placed in the presence of a magnetic field. A paramagnetic sensor uses this fact to determine oxygen concentration.
  • The sample enters the enclosure containing a torsion balance suspended in a magnetic field.
  • An oxygen containing sample will cause the cause the balance to deflect from its zero position.
  • A photodetector measures the deflection and provides a feedback current to restore the torsion balance to its zero position.
  • The feedback current is directly proportional to oxygen levels in the sample after calibration.
OMA-406-O2 Paramagnetic Oxygen Detection

Spectroscopy

To analyze the chemical composition of the sample, the OMA uses an analysis method known as ultraviolet-visible (UV-Vis) spectroscopy. The system measures absorbance from 200nm to 800nm and quantifies the amount of light absorbed by the sample at each integer wavelength; the OMA plots this raw data to visualize a high-resolution absorbance spectrum. Learn more

Spectrophotometer Principle of Operation

The OMA uses a long-life xenon light source to transmit a signal through the sample fluid in the flow cell. The signal is carried by fiber optic cables from the analyzer to the flow cell, where the chemical mixture of the sample has unique interactions with the light based on its current composition. Learn more

Optical Assembly

Specifications

General
Detector nova II™ spectrophotometer, paramagnetic oxygen detector
Spectrometer Light Source Standard: pulsed xenon lamp with average 5 year life span
Fiber Optic Cables Standard: 600 μm core 1.8-meter fiber optic cables (qty = 2)
Process Connection 1/4” tubing compression fitting (flow cell) and 1/8” tubing compression fitting (oxygen detector)
Calibration If possible, the instrument is factory calibrated prior to shipment; Monthly calibrations are required to keep O2 sensor within specification. Spectrophotometer does not require calibration after the initial calibration.
Human Machine Interface Industrial controller with touchscreen LCD display running ECLIPSETM software
Data Storage Solid state drive
Measuring Parameters
Accuracy Spectrometer: ±2% full scale range
Response Time Readings every 1-5 seconds
Sample Parameters
Sample Temperature Standard: 0 to 65 °C
Contact AAI for temperatures above these ranges
Sample Pressure Standard: -5 psig to 5 psig
Sample Medium Gas
Flow Rate 50-200ml/min
Ambient Conditions
Analyzer Environment Indoor
Ambient Temperature Standard: 0 to 35 °C (32 to 95 °F)
Ambient Altitude -250 m to 5,000 m (-770 ft to 15,400 ft)
Physical Specifications
Dimensions 8.90" H x 19.02" W x 14.29" D (226mm H x 483mm W x 363mm D)
Analyzer Weight 30 lbs. (14 kg)
Wetted Materials Flow cell: fused silica, viton, 316L stainless steel
Oxygen sensor: 316 stainless steel, viton, borosilicate glass, electroless nickel,
platinum/iridium alloy
Electrical Requirements 85 to 264 VAC 47 to 63 Hz
Power Consumption 45 Watts
Outputs 1x galvanically isolated 4-20mA analog output per measured analyte 2x digital outputs for fault and SCS control
Optional: Modbus TCP/IP; RS-232; RS-485; HART;
Contact AAI for options not listed