Natural Gas & The Smell of Safety

natural gas and the smell of safety

Why measure odorant level in natural gas?

Unlike modern industrial zones, where safety regulations demand constant monitoring of ambient gases, people in residential areas typically have only one recourse for detecting natural gas buildup: their noses.

On its own, natural gas is technically odorless. The distinctive smell is artificially added solely for the purpose of human detection: US law, for example, requires that all natural gas be detectable by a human with a normal sense of smell when the gas concentration exceeds 1/5 of its lower explosive limit (LEL), i.e. well below the threshold at which natural gas can ignite in air.

To odorize the natural gas, distribution companies inject chemical odorants (typically blends of mercaptans) into their pipeline system. This injection is a sensitive procedure: too little odorant makes the gas unsafe for distribution, but too much odorant makes the product overly unpleasant and wastes resources.

In order to monitor the odorant level in natural gas, distributors have traditionally dispatched designated “sniffers” – humans who sniff gas samples and assess odor rating at a specific pipeline sampling point. Aside from being an unhealthy practice, this method is imperfect because sniffers are subjective; humans can have inconsistent olfactory response due to diet, sickness, or developed tolerance. Even the most objective sniffers will be thwarted by chemical phenomena in the pipeline such as adsorption or odorant fading/masking.

The future of odorant analysis

With safety regulations growing increasingly stringent, many pipeline operators are turning to modern analytical methods to supplement or replace the human sniffer method. Using dispersive UV-Vis absorbance spectrophotometry, the OMA-300 measures the concentration of up to 5 odorant species simultaneously in a continuously drawn natural gas sample.

Critical advantages of the OMA over human sniffing include (1) objective analysis normalized regularly by Automatic Zero; (2) 24-hour analysis for rich trend data; (3) fast response to sudden changes in odorant level; (4) reduced exposure of humans to toxic samples; (5) reduced cost of operation by slashing travel time and workload of human sniffers.

The safety of OMA

Watch this video demo which explains why the OMA is the world’s safest online analyzer for toxic sulfur compounds such as the species monitored in odorant analysis.

More information
1. Application Note   2. OMA Series 

Our Tail Gas Probe v3 Now Available!

Tail Gas Probe v3

Since 2014, we have been field-testing a major update to the probe design for our TLG-837 Tail Gas Analyzer — the most trusted H2S/SO2 ratio monitor in the sulfur recovery industry. We are excited to announce the official launch of DEMISTER Probe v3!

The New Isolation Valve

On previous probe versions, the ball valve allows the user to retract the probe from the process pipe to perform maintenance. In DEMISTER Probe v3, we introduced a bonnet-style shutoff valve directly in the probe head with which you can internally seal the process at the sample entrance port. This safe, quick method to access the sample flow cell completely eliminates the need to retract the probe during maintenance!

Our case studies exceeded our own expectations: engineers reported that the maintenance procedure of cleaning the optics (recommended monthly) is 75% faster when using the isolation valve than when retracting the probe.

Redesigned Cooling Extensions

On the TLG-837, the cooling extensions increase the distance between the fiber optic collimators and the flow cell, protecting the optics from damage due to conductive heat transfer. Thanks to user feedback, we relocated the sealing o-rings from the probe head to the body of the removable cooling extension itself, making them much more accessible for routine inspections. Don’t worry — the new cooling extensions retrofit into all of our previous DEMISTER Probe versions.